Twin QuadPlexer E15V90P43
RM0.00
Description
Product Specifications
|
General Specifications |
Product Family | CBC18212326 |
Modularity | 2-Twin |
Includes | Mounting hardware |
Electrical Specifications |
Sub-module | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 |
Branch | 1 | 2 | 3 | 4 |
Port Designation | 1800 | 2100 | 2300 | 2600 |
License Band | DCS 1800
| IMT 2100
| WCS 2300
| IMT 2600
|
|
Electrical Specifications, Band Pass |
Frequency Range | 1710–1880 MHz
| 1920–2170 MHz
| 2302–2400 MHz
| 2500–2690 MHz
|
Insertion Loss, typical | 0.40 dB | 0.40 dB | 0.35 dB | 0.30 dB |
Return Loss, typical | 20 dB | 20 dB | 20 dB | 20 dB |
Isolation, minimum | 50 dB | 50 dB | 50 dB | 50 dB |
Input Power, RMS, maximum | 300 W | 300 W | 300 W | 300 W |
3rd Order PIM, typical | -160 dBc | -160 dBc | -160 dBc | -160 dBc |
3rd Order PIM Test Method | Two +43 dBm carriers
| Two +43 dBm carriers
| Two +43 dBm carriers
| Two +43 dBm carriers
|
Product Classification |
Product Type | Quadplexer |
|
AISG Electrical Specifications |
AISG Carrier | 2176 KHz ± 100 ppm |
Insertion Loss, maximum | 0.50 dB |
Return Loss, minimum | 10 dB |
|
dc Power/Alarm Electrical Specifications |
dc/AISG Pass-through, combiner | Branch 1 | Branch 2 | Branch 3 | Branch 4 |
dc/AISG Pass-through, demultiplexer | Branch 1 | Branch 2 | Branch 3 | Branch 4 |
Lightning Surge Current | 5 kA |
Lightning Surge Current Waveform | 8/20 waveform |
|
Electrical Specifications |
Impedance | 50 ohm |
Mechanical Specifications |
RF Connector Interface | 7-16 DIN Female |
RF Connector Interface Body Style | Medium neck |
Color | Gray |
Mount Type | Pole | Wall |
Mounting Pipe Diameter | 42.6–122 mm |
Mounting Pipe Hardware | Band clamps (2) |
Wind Speed, maximum | 60 m/s |
|
Dimensions |
Height | 205.0 mm | 8.1 in |
Width | 250.0 mm | 9.8 in |
Depth | 113.0 mm | 4.4 in |
Weight | 7.6 kg | 16.8 lb |
|
Environmental Specifications |
Operating Temperature | -40 °C to +65 °C (-40 °F to +149 °F) |
Relative Humidity | 15%–100% |
Ingress Protection Test Method | IEC 60529:2001, IP67 |
Corrosion Test Method | IEC 60068-2-11, 30 days |
Vibration Test Method | IEC 60068-2-6 |